MW.MODEL#.STATE

This command allows you to specify which MechaWare models run. There is a command for each model loaded on the drive. The value of the command specifies whether the model runs (1) or is disabled (0).

Models 1-4 are Factory Models loaded by Kollmorgen. Models 5-8 are User Models.

Example

Enable Model 1:

-->MW.MODEL1.STATE 1

Get the excitation current (already set to 0.2 A):

-->MW.MODEL1.STATE
1

Versions

Action Version Notes
Implemented 02-00-00-000  

General Information

Type Read/Write
Description Sets the operating state of the Kollmorgen Automation Suite model
Units N/A
Range 0-1
Default Value 1
Data Type Integer
Stored in Non-Volatile Memory Yes

Variants Supported

All variants are supported.

Industrial Ethernet Information

EtherCAT CoE and CANopen

Command

Index

SubIndex

Data Type

Units

Float Scale

Access

PDO Mappable

MW.MODEL1.STATE

30e3h

01h

Unsigned8

-

-

Read/Write

No

MW.MODEL2.STATE

30e3h

02h

Unsigned8

-

-

Read/Write

No

MW.MODEL3.STATE

30e3h

03h

Unsigned8

-

-

Read/Write

No

MW.MODEL4.STATE

30e3h

04h

Unsigned8

-

-

Read/Write

No

MW.MODEL5.STATE

30e3h

05h

Unsigned8

-

-

Read/Write

No

MW.MODEL6.STATE

30e3h

06h

Unsigned8

-

-

Read/Write

No

MW.MODEL7.STATE

30e3h

07h

Unsigned8

-

-

Read/Write

No

MW.MODEL8.STATE

30e3h

08h

Unsigned8

-

-

Read/Write

No

EtherNet/IP

ID

Instance

Attribute

Name

Data Type

Access

User Mappable

2801

1

2801 (0xaf1)

MW.MODEL1.STATE

Unsigned8

Read/Write

Yes

2802

1

2802 (0xaf2)

MW.MODEL2.STATE

Unsigned8

Read/Write

Yes

2803

1

2803 (0xaf3)

MW.MODEL3.STATE

Unsigned8

Read/Write

Yes

2804

1

2804 (0xaf4)

MW.MODEL4.STATE

Unsigned8

Read/Write

Yes

2805

1

2805 (0xaf5)

MW.MODEL5.STATE

Unsigned8

Read/Write

Yes

2806

1

2806 (0xaf6)

MW.MODEL6.STATE

Unsigned8

Read/Write

Yes

2807

1

2807 (0xaf7)

MW.MODEL7.STATE

Unsigned8

Read/Write

Yes

2808

1

2808 (0xaf8)

MW.MODEL8.STATE

Unsigned8

Read/Write

Yes

PROFINET

Parameter

PNU

Data Type

Access

Units

MW.MODEL1.STATE

2801

Unsigned8

Read/Write

-

MW.MODEL2.STATE

2802

Unsigned8

Read/Write

-

MW.MODEL3.STATE

2803

Unsigned8

Read/Write

-

MW.MODEL4.STATE

2804

Unsigned8

Read/Write

-

MW.MODEL5.STATE

2805

Unsigned8

Read/Write

-

MW.MODEL6.STATE

2806

Unsigned8

Read/Write

-

MW.MODEL7.STATE

2807

Unsigned8

Read/Write

-

MW.MODEL8.STATE

2808

Unsigned8

Read/Write

-